Showing posts with label experiment notes. Show all posts
Showing posts with label experiment notes. Show all posts

Wednesday, February 6, 2008

Little experiment for today

It was not I who was doing it.
Our respectable senior technician was taking photos of my little norms and mutants that I made last week. He was so skillful and serious, and was capable of any subtle movement to ajust everything to its best state! In fact I guess his movement must be of micro or nano-scale precision. What an exhibition of great spirit of Japanese craftsmanship! He is not exactly a craftsman but he did make the best Microscopic photos all the time.

Wednesday, January 30, 2008

exp_{week} (3rd Day)

No trouble but troublesome.
Megohmmeter is suffering bad connection or a serious health problem. An examination is to be done.

-------
14:50 Then the trouble came
Lesson:
If the damage is small (say less than 500), just close shutter and take time to fix.
If it is much more than 500, stop immediately and prepare to redo it.
Or try to make some interesting mutant out of the damaged material.

-------

Tuesday, January 29, 2008

2nd day of exp(week)

Everything seems to be fine except the cooling water which is leaking 1~2 drops /day. It's dangerous but not so terribly dangerous now, so we are going to fix it some time this week. Hope it will take place on Friday so that I can realy complete something this week.

The high voltage power source is doing ok though a little noisy because of micro thunder inside.

Monday, January 28, 2008

1st day of the experiment week

After a weekend's relax, cryopump is full of gas vapour that was once condensed on the metal plate during pumping process of the previous week. It needs a restart.

1. Restart cryogenic pump


1.0 Get rid of the gas inside of the Cryogenic pump by using roughening pump.

1.0.1. Before doing anything (that one may regret later) make sure that:

  • no contact between roughening pump and main chamber
  • no contact between roughening pump and outside
  • no contact between cryogenic pump and outside.
1.0.2 Connect roughening pump with Cryogenic pump  make sure that the wire is connected and then turn the switch (that connect crogenic pump and roughening pump) on, there is a mechanic sound to confirm that the corresponding parts (inside) moved.

1.0.3 Turn on the roughening pump.
(It is a little better to turn on the roughening pump before turning on the switch, I feel)

1.1 Start the Cryogenic pump

When the pressure inside Cryogenic pump is about 70~100 mTorr.

1.1.1 Turn off the switch that that connect cryogenic pump and roughening pump, disconnect the wire of the switch from power, and turn off the roughening pump.

1.1.2 Turn on the cooling water for Cryo pump and then turn on the power of the Cryo pump.The temperature inside of Cryo will drop quickly from 293 K to 150 K within an hour (or 30 min, I forgot?).

2 hours later the temperature should stay at 8 K which is the working temperature of Cryo.

If the temperature didn't drop to 8k within 2 hours, the process of starting Cryo failed and one have to know the reason why it failed and prepare to start it the next day (wait a whole day for the condensed gas to vapor so that it's possible to be evacuated by roughening pump). The reason of failure is always that the 1.o process failed so that vacuum inside of Cryo was so bad that temperature can never drop to 8 K (too many gas molecules keep taking heat from the shell of cryo which is about the temperature of outside environment.)